J Transcat Intervent.2021;29:eA20200034.

Correction of extensive mitral paravalvular leak with three occlusion devices via transapical access: a case report

Luiz Eduardo Koenig São Thiago ORCID logo , Luis Sérgio Carvalho Luciano ORCID logo , Ana Luísa Corrêa Vieira Rabelo ORCID logo , Willian Junkes da Conceição ORCID logo , Leandro Waldrich ORCID logo , Luiz Carlos Giuliano ORCID logo

DOI: 10.31160/JOTCI202129A20200034

ABSTRACT

Heart valve diseases account for a significant portion of hospitalizations due to cardiovascular diseases in Brazil. Prosthetic heart valves, which are often part of treatment, are susceptible to complications, such as paravalvular leak. Surgical intervention remains the treatment of choice for correcting this defect. However, transesophageal echocardiography-guided catheter correction has emerged as a less invasive alternative for paravalvular leak treatment in patients at high surgical risk. We report a case of extensive mitral paravalvular leak in a patient who had two previous cardiac surgeries and a high surgical risk, who underwent successful transcatheter closure with three prosthesis implantation by transapical access.

Correction of extensive mitral paravalvular leak with three occlusion devices via transapical access: a case report